Water Chiller

Water Chiller

inquiry
  • Water Chiller Specification
    Model
    Item
    AC-2 AC-3 AC-5 AC-6 AC-8 AC-10 AC-12 AC-15 AC-20 AC-25 AC-30 AC-40 AC-50
    Nominal cooling Capacity Kcal/h
    50HZ/60HZ
    5332 7955 12126 14706 19522 25886 30014 38012 51772 60028 76024 103544 120056
    6398 9546 14551 17647 23426 31063 36017 45614 62126 72034 91229 124253 144067
    KW
    50HZ/60HZ
    6.2 8.5 14.5 17.1 22.7 29 36.5 43.5 58 73 92.7 123.6 146
    4.10 7.44 13.62 17.40 20.40 27.24 37.10 40.86 54.48 74.20 85.50 114.00 148.40
    Input power KW 2.25 3.2 5.53 5.93 8.08 11.22 12.32 15.8 21.36 23.56 31.36 39.6 46.72
    Power supply 1P220V 50/60HZ 3PH~380V 50HZ(200V/220V/415V /460V 50HZ/60HZ)
    (110V 50HZ/60HZ)
    Refrigerant type R22(R134A/407C/R410A)
    type of control capillary Expansion valve
    Compressor type hermetic rotary Hermetic scroll type (piston)
    power(kw) 1.73 2.64 4.4 4.8 6.1 8.8 9.9 13.2 17.6 19.8 24.6 32.8 39.6
    condenser type High efficient finned copper tube + low noise outer rotor fan
    Power(kw) 0.15 0.19 0.38 0.38 0.48 0.92 0.92 1.1 1.56 1.56 2.76 2.8 3.12
    cooling air flow(m3/h) 2000 3000 5000 6000 8000 10000 12000 15000 20000 25000 30000 40000 50000
    Evaporator type shell and tube+water tank
    chilled fluid flow(m3/h) 1.07 1.47 2.50 2.95 3.91 5.00 6.29 7.50 10.00 12.59 15.98 21.31 25.17
    0.71 1.28 2.35 3.00 3.52 4.70 6.40 7.04 9.39 12.79 14.74 19.66 25.59
    Volume(L) 22 50 60 75 120 200 200 300 350 350 460 580 620
    inlet and outlet pipe diameter (inch) 1/2" 1" 1" 1" 1-1/2" 1-1/2" 2" 2" 2" 2-1/2" 2-1/2" 2-1/2" 3"
    water pump power (kw) 0.37 0.37 0.75 0.75 1.5 1.5 1.5 1.5 2.2 2.2 4 4 4
    lift(m) 20 20 20 20 20 20 20 20 20 20 22 22 22
    safety protection compressor overheating protection, over-current protection, high and low pressure,over-temperature protection, flow switch, protection,phase sequence or missing phase protection, exhaust overheating protection
    dimension L(mm) 750 930(1200) 1140(1300) 1140(1300) 1530(1600) 1530(1600) 1530(1600) 1850(1900) 2150(2200) 2150(2200) 2150(2350) 2100(2350) 2350
    W(mm) 500 520(560) 560(650) 560(650) 780(850) 780(850) 780(850) 990(1050) 1130(1300) 1130(1300) 1480(1480) 1660(1800) 1760
    H(mm) 948 1185(1280) 1250(1380) 1250(1380) 1630(1810) 1630(1810) 1630(1810) 1870(1960) 1820(2020) 2000(2020) 1950(1900) 2100(2150) 2100
    weight Kg 100 135 175 180 310 450 530 750 835 920 1150 1250 1450

    Note:

    1.Nominal cooling capacity is according to:

    Inlet chilled fluid temperature: 17℃

    Outlet chilled fluid temperature: 12℃

    Inlet cooling air temperature: 30℃

    Outlet cooling air temperature: 35℃


    2. Working Range:

    The temperature range of chilled fluid is from 5℃ to 35℃;

    Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.

    It is better to run the chiller while the ambient temperature at or below 35℃.

    We reserve the right to modify the above dimensions or parameters without further notice.